EKL6-100B 10kA Electromagnetic type B RCCB with DC 6mA Protection
EKL6-100B 10kA Electromagnetic type B RCCB with DC 6mA Protection
EKL6-100B 10kA Electromagnetic type B RCCB with DC 6mA Protection

EKL6-100B 10kA Electromagnetic type B RCCB with DC 6mA Protection

feedback
Product Description

EKL6-100B Type B RCD has novel appearance design, compact structure, good reliability, and high safety. They ensure higher protection levels with maximum operational continuity under all working conditions.Type B RCDs are suitable for non-linear circuits that can generate leakages with high direct current (> 6 mA) and/or high frequency components;Type B RCDs can ensure maximum safety in many applications,such as EV Charging Station,Crane and Elevator,PV and Wind power plants,etc.

Electrical Features Mode Electromagnetic
Type (wave form of the earth leakage sensed) B
Rated current In 25,40,63A
Poles 2P, 4P
Rated voltage Ue 2P 240V~, 4P 415V~
lnsulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operation current(I△n) 30mA
Rated residual operating current(I△dc) 6mA
Rated residual making and breaking capacity (IAm) 500A(In≤40A), 10In(In>40A)
Short-circuit current Inc=l△c 10,000A
SCPD fuse
Break time under l△n ≤0.1s
Rated impulse withstand voltage(1.5/50) Uimp 4000V
Dielectric test voltage at ind.Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles
Installation Contact position indicator Yes
Protection degree IP20
Ambient temperature(with daily average≤35℃) -5℃~+40℃
Storage temperature -25℃~+70℃
Terminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable 35mm2  18-3AWG
Terminal size top/bottom for busbar 35mm2  18-3AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply in both directions
Tripping Current Range Lagging Angle I△n>0.01A I△n≤0.01A
0.35I△n≤I△≤1.4I△n 0.35I△n≤I△≤2I△n
90° 0.25I△n≤I△≤1.4I△n 0.25I△n≤I△≤2I△n
135° 0.11I△n≤I△≤1.4I△n 0.11I△n≤I△≤2I△n

 

Alternative Current Sensitive Pulsating direct current sensitive Surge current proof

B class

Tripping is ensured for sinusoidal AC
Residual currents pulsed DC residual currents,
alternating residual sinusoidal currents up to 1000Hz,
pulsating direct residual currents
and for smooth direct residual currents,
whether applied suddenly or increasing slowly.

They react to AC and pulsating DC 
fault current which reach 0 or almost 
0 within one time period of the 
mains frequency.

RCCB's surge capacity.
Not tripping at standardized 8/20 υs 
surge-current waves acc.to VDE 0432 
Part 2 with surge current values of up 
to 250A.

 

Circuit Diagram

 

Overall and Installation Dimension (mm)